Home About us News Products Support Maintenance recruitmen Contact us
 
Network Analyzer
multiport test set
Mr Zheng,General President  
Huoju Building,9th floor
Chuangye Road,Chengdu ,China
Tel:+86 028 85157401
Fax:+86 028 85157403
Email:13908052495@163.com
 
 
 
 
Recommended products >>
 
TD3619C Vector Network Analyzer

Main Feature
l          WindowsXP Operation System
l          4 Port Test Mode / 2 port Test Mode
l          10.4 Inch TFT LCD
l          MultiWindows、MultiChannel、MultiTrace can be displayed at one time
l          Timefield Function
 
 
Main Specification:
Test Port Output
l          Frequency Range:   100kHz~8.5GHz,
l          Frequency Resolution:1 Hz
l          CW Accuracy:±5 ppm, 23°C±5°C
l          Output Power range:-55dBm~+10dBm
l          Level Resolution:0.05dB
l          Level Accuracy :
±0.65 dB (at 0 dBm, 50 MHz absolute)
±1.0 dB (at 0 dBm, relative to 50MHz reference)
l          Level Linearity :±0.75dB
l          Harmonics:<-20dBc(at +5 dBm,typical)
l          Non-Harmonic Spurious:
           < −30 dBc (at +5 dBm, typical)
 
l          Extenal PortUSB、LAN、RS232、PS/2、Parrallel、   VGA、GPIB(option)
l          Impedance: 50Ω
l          Test portN female 4/2 port
l          FormatLog,Lin,Delay,Smith,SWR,Polar,Real,     Imaginary
l          Limit testRipple limit test,Bandwidth limit test
 
System Performance
System Dynamic Range 118 dB(IF bandwidth 10 Hz)
Directivity
1MHz~10MHz   46dB
10MHz~3GHz   43dB
3GHz~6GHz    37dB 
6GHz~8.5GHz  35dB
System impedance 50Ω
Test portN female
Power:
AC 150V~230V/50~60Hz; 350VAMax
Weight: 20kg
Dimension: 490×427×234mm
 


 

Test Port Input
l              Maximum Input Level:+10dBm
l              Damage Level: +26dBm  ±35VDC, typical
 
 
Option Table:


Option :245
100kHz~4.5GHz 2-port
Option :001
English
Option :265
100kHz~6.5GHz 2-port
Option :1E9
touch screen
Option :285
100kHz~8.5GHz 2-port
Option :1E10
GP-IB card
Option :445
100kHz~4.5GHz 4-port
Option :1E8J
N-50J calibration Kit( open, short, load, adapter)
Option :465
100kHz~6.5GHz 4-port
Option :1E8K
N-50K calibration Kit ( open, short, load, adapter)
Option :485
100kHz~8.5GHz 4-port
Option :1E9J
SMA-50J calibration Kit ( open, short, load, adapter)
Option 1E9K
SMA-50K calibration Kit ( open, short, load, adapter)

 
 

 The previous:none
  Print this page || Close the window
 
Home | About us | News | Products | Support | Maintenance | recruitmen | Contact us
                Address:No16,Chuangye road,Chengdu,Sichuan,China
                Tel:(0086)28-85157401     
E-mial:zzx@cdtianda.com  Fax85157403